Frequently Asked Electrical Questions

Do I have to wait all day for your electrician?
No, we provide 2 hour time slots for our electrician to arrive. The vast major ity of call-out wor k can be completed in less than an hour

Do you provide free quotations?
For larger projects such as lighting design, LCD wall mounting and AV installations, house rewires etc. we will provide you with a free quotation. Obviously, it is not cost effective for us to send someone to quote for a repair. In that instance we charge £75 per hour + VAT, with a 1 hour minimum charge

Are your electricians qualified?
Yes, all our electricians are NAPIT or NICE qualified.

Are you insured?
Yes, we carry £2 Million wor th of insurance

Q: What is an RCD?
A: RCD stands for Residual Current Device. These are what use to be called ELCB�s (Earth Leakage Circuit Breakers). They are usually fitted as standard to most domestic consumer units in houses built after about 1980. Note that they tend to only protect certain parts of the distribution panel wiring (e.g. the kitchen or utility ring main), in a so-called �split-load� consumer unit. They are designed to quickly trip and interrupt the supply to the circuit they are protecting, when an imbalance is detected between the neutral and live in the case of an RCD, or when there is a current in the earth wire of the protected circuit, above a preset limit (usually 30mA), in the true ELCB. You can also purchase �plug-in� ones, ideal for mowers, vacuums, and hair dryers, and an RCD plug (replaces the plug), for things like shower pumps. For an excellent article on how an RCD wor ks, see the TLC ARTICLE. Although the primary protection is the fuse in the plug, these do not blow for some fault conditions, and they are there mainly to protect the wiring and the appliance from overloads. To protect the user from shocks and earth leakage faults, the RCD is ideal for this.

Q: My RCD on the consumer unit trips out, what do I do?
A: If this is a solid fault (i.e. it won�t reset), it is most likely due to a faulty appliance that is plugged in all the time, but has developed a fault that is creating a current to earth, or a current in the live not all going though the neutral part of the protected circuit. Most likely culprits are the washing machine, dishwasher, or dryer. Try unplugging each one in turn, until the RCD holds latched in the ON state. If it is not one of those items, and your Freezer is also on that circuit, try unplugging that too. If that is NOT the problem appliance, do not open the door , get an extension lead, and plug it into another room plug as a tempor ary measure (on a circuit not affected), until you locate the faulty appliance. Other culprits can be a kettle, or steam iron, (usually anything that comes into contact with water!). However, don�t for get that even small things like radio alarm clocks, and plug-in timers, chargers, and mains adaptor s can cause the RCD to trip out, so go around and check ALL your items. If you still cannot find the problem, call in a professional tradesman.

Q: How do I change a lamp pendant or ceiling rose?
A: Firstly ensure all power is off to the lighting circuit you are dealing with. Unscrew the ceiling rose cover, and remove the old pendant fitting. In case the wiring is different to that shown in the diagram, make a note of it. Note also that the new wiring colours may now be used in new houses, as the IEE have released an emendment to the BS7671:2001 (IEE Wiring Regulations) in March 2004. The wiring in the ceiling will be either 1.0 or 1.5mm flat twin and earth suitable for lighting. See http://www.iee.or g/cablecolours for an article on this. TLC also has some excellent infor mation about this, at: http://www.tlc-direct.co.uk/Technical/DataSheets/Cable/Index.htm The new fitting (chandelier etc) may not have room, or cover the existing base, so if it has to be removed, carefully rewire all the existing wiring into an appropriately sized connector block, following the cor rect wiring scheme. If this is a bedroom or landing fitting, you may find it easier to fit a junction-box in the loft, just near to where the fitting will be then connecting up with a single piece of twin and earth.

Wire

Electrical Services

Our services include: House wiring, commercial electrical contractor s, industrial electrian, home electrical rewiring, pre-purchase electrical repor ts for house buyers, burglar alarm fitting, Audio Visual services, electrical fault diagnosis and lighting installations.

Pen

Free Quotations

We provide FREE quotations
Fully specified with no obligation to you.

We are part of Serviceteam - providing household services to the domestic and commercial markets.

Happy Woman

Customer Satisfaction

We understand that customer satisfaction is key to the success of any firm. That's why we wor k hard to ensure that our customers receive a quality of service that continues to build our reputation.

Black Telephone

Contact Us

For mor e infor mation on our full range of electrical services, call us on 0800 599 9750 or contact us.



Industrial electrician Westminster SW1 Industrial electrician Belgravia SW1 Industrial electrician Pimlico SW1 Industrial electrician Victor ia SW1 Industrial electrician Brixton SW2 Industrial electrician Chelsea SW3 Industrial electrician Clapham SW4 Industrial electrician Earl's Court SW5 Industrial electrician Fulham SW6 Industrial electrician South Kensington SW7 Industrial electrician Vauxhall SW8 Industrial electrician Stockwell SW9 Industrial electrician Battersea SW11 Industrial electrician Clapham Junction SW11 Industrial electrician Balham SW12 Industrial electrician Barnes SW13 Industrial electrician East Sheen SW14 Industrial electrician Putney SW15 Industrial electrician Streatham SW16 Industrial electrician Tooting SW17 Industrial electrician Wandswor th SW18 Industrial electrician Earlsfield SW18 Industrial electrician Wimbledon SW19 Industrial electrician Merton SW19 Industrial electrician Collier's Wood SW19 Industrial electrician Raynes Park SW20 Industrial electrician London

Navigation